Jackson 1295 Rim Panic Bar Installation Instructions

DOOR PREPARATION
1. Place door horizontally on stands, interior side up.
2. Mark stile centerlines Y-lines, 1-1/8" (28.6) from outside edge for all stile widths. (Fig. 1)
3. Mark stile X-lines per template instructions. (Fig. 2)
4. Attach corresponding templates. (Fig. 2)
DOOR HARDWARE INSTALLATION
INSTALLATION OF OPTIONAL RIM CYLINDER
NOTE: Optional Rim Cylinder must be installed before attaching exit device.
1. Attach the Rim Cylinder on door stile with (2) 1-7/8" (47.6 mm) Breakaway Screws provided. Fig. 9

INSTALLATION OF EXTERNAL TRIM (OPTIONAL)
NOTE: Exterior trim must be installed before attaching exit device.
1. Attach the exterior trim with F (2) #10 x 2-1/8" Flat head screws provided shown in Fig. 10.

INSTALLATION OF 1295 RIM PANIC EXIT DEVICE
DOOR HARDWARE INSTALLATION (CONTINUED)
1. Attach exit panic device to door with (2) 12-24 x 3/4" FHMS on active stile and (1) 1/4"-20 x 1/2" PHSMS at end cap bracket on inactive stile as shown in Fig. 11.
INSTALLATION OF END CAPS AND COVER PLATES
1. Slide the (2) base cover plates 302674 and 30267448 in place.
2. Attach both end caps to the previously attached end cap brackets with (4) 8-32 x 1/4" FHMSRefer to (Fig.12).
FRAME PREPARATION
Mounting Instructions
1. Prepare Lock Stile per Template, drill Cylindermounting holes if required.
2. Locate Centerline of Cylinder on exterior of Doorand drill if required.
3. Trim Tail Piece to fit into Panic Drive Bushing Assembly.
4. Mount Cylinder and secure with mounting screws.(Supplied by lock mfg.) If trim is required prepareper Template.
5. Locate mounting hole on Inactive Stile.Drill and tap 1/4"-20 Thds. 40" (1016) from the bottom ofthe Door.
Panic Attachment
1. Remove front and rear Base Cover Plates by removing(4) 8-32 x 1/4" Flat HD Screws. Secure active end ofpanic by installing (2) 12-24 x 3/4" Flat HD MS.Secure inactive end with single 1/4"-20 x 1/2" PanHD SMS through Base Cover Plate Bracket. Re-installBase Cover Plates on each end of Panic Base.
2. To install "C" Strike, locate 10-24 tap holes onActive Stile (2 places).
3. Mount and secure "C" Strike.
4. Check operation of all parts including Cylinder(if applicable) to assure proper operation.
Dogging Instructions
To Dog: Insert hex dogging key. Turn key clockwise until it stops. Depress and hold the push bar then release the key. Push bar will remain depressed. Remove key. (Fig. 14)
To Undog: Insert hex dogging key and turn clockwise until it stops. While depressing push bar turn and remove key. Push bar will become operable again (Fig. 15).















Need Help?