Time Delay Relay Board Great For Integrating Electric Strikes, Electrified Exit Devices, Mag Locks, Or Any Other Locking Hardware Requiring A Time Delay Before Triggering
The American Entrance Controls universal door controller is a time delay relay sequencer board. It's main function is providing an adjustable time delay to trigger electronic door hardware. Electric strikes, maglocks, electrified exit devices need to trigger before an automatic door opener can power a door open. This device offers and adjustable delay allowing the electric lock to release or unlatch before an automatic door operator powers the door open. However, this device is not limited to automatic door opener integration. The American Entrance Controls universal door controller time delay relay can be used for any access control application where a time delay is required to trigger certain electronic devices before the other. This time delay board is a great add on to any of the American Entrance Controls power supplies.
American Entrance Controls Universal Door Controller Applications
- ADA Automatic Door Opener Integration
- Electric Strike Integration
- Maglock Integration
- Electrified Exit Device Integration
- Touchless Activation Switch Integration
- Push To Open or Request To Exit Integration
- Security Entrance Applications
- Telephone or Gate Entry
American Entrance Controls Universal Door Controller Features
- Bi-Directional Sequencing Mode
- 3 Adjustable Time Delays, Up To 30 Seconds
- Easy To Use Potentiometer Adjustments
- Watchdog LED's For Relay Indication
- Wet or Dry Inputs
- 12 or 24 VAC/VDC
- SPDT Contacts Are Rated 3 Amps @ 30VDC
American Entrance Controls Universal Door Controller Specifications
- Board Dimensions: 3.25" x 2.25" x 0.75"
- Includes Velcro or Double Sided Tape For Easy Mounting In A Power Supply Panel
- Board Is Enclosed In A Protective Paper Sleeve
- Operation Voltage: 12 or 24 VAC / VDC
- Current Draw: 18 mA Stand By, 40 mA max.
- Response Time: 0.3 seconds
- 2 Each Wet Input Contacts
- 2 Each Dry Input Contacts
- Inputs are 3-30 VAC/VDC, Optically Isolated and Non Polarity Sensitive
- 2 Each Form C (SPDT) Relay Outputs
- Relay Contact Rating: 3 Amps @ 20 VDC
- 3 Each Adjustable Time Delays
- Relay #1 (DOR #1): Adjustable 1 to 30 seconds
- Relay #2 (DOO #2): Adjustable 1 to 30 seconds
- Relay #3 (DOR #2) Adjustable 1 to 30 seconds
- Tested For 100,000 Operations @ Rated Capacity and 500,000 Operations @ 50% Rated Capacity